- Home
- Thermostats
- 01172.0-01 ZR011 Enclosure Dual Thermostat NC NO Heat & Cool 32 to 140°F
Product Description
- NC / NO or NO / NO in one unit
- Separate adjustable temperatures
- Color coded temperature dials
- DIN rail mountable
The ZR011 has two separate thermostats in one housing: This allows the independent control of heating and cooling equipment, or signaling equipment.
Thermostat - NC (normally closed): Opens on temperature rise (red temperature dial) - for regulating heaters or for switching signal devices when temperature has fallen below the minimum value.
Thermostat - NO (normally open): Closes on temperature rise (blue temperature dial) - for regulating filter fans, heat exchangers, or for switching signal devices when temperature limit has been exceeded.
| Switch temperature difference | 12.6°F ± 7°F tolerance (7°K ± 4°K) |
| Sensor element | thermostatic bimetal |
| Contact type | snap-action contact |
| Service life | > 100 000 cycles |
| Max. switching capacity | NC: 10A resistive / 2A inductive @ 250VAC |
| NO: 5A resistive / 2A inductive @ 250VAC | |
| 15A resistive / 2A inductive @ 120VAC | |
| DC 30W (24-72Vdc) | |
| Max. inrush current | 16A VAC for 10 seconds |
| Connection | 4-pole terminal, clamping torque 0.5Nm max.: solid wire 14 awg (2.5mm²) / stranded wire (w/ wire end ferrule) 16 awg (1.5mm²) |
| Housing | plastic according to UL94 V-0. light grey |
| Mounting | molded plastic clip for 35mm DIN rail, EN60715 |
| Mounting position | vertical |
| Operating/Storage temperature | -49 to +176°F (-45 to +80°C) |
| Operating / Storage humidity | max. 90 % RH (non-condensing) |
| Dimensions | 2.6x2.0x1.8" (67 x 50 x 46mm) |
| Weight | approx. 3.2 oz (90g) |
| Protection type | IP20 |
| Approvals | UL File No. E164102, CSA, VDE, EAC |
| Part No. | Setting range (NC) | Setting range (NO) | Approvals | CSA | VDE | EAC |
| 01172.0-00 | 0 to +60°C | 0 to +60°C | UL File No. E164102 | |||
| 01172.0-01 | +32 to +140°F | +32 to +140°F | UL File No. E164102 | |||
| 01175.0-00 | -10 to +50°C | -20 to +80°C | UL File No. E164102 | CSA | VDE | EAC |
| 01175.0-01 | +14 to +122°F | +68 to +176 °F | UL File No. E164102 | CSA | VDE | EAC |
| Part No. | Setting range (NO) | Setting range (NO) | Approvals | |||
| 01176.0-00* | 0 to +60°C | 0 to +60°C | UL File No. E164102 | CSA | VDE | EAC |
| 01176.0-01* | +32 to +140°F | +32 to +140°F | UL File No. E164102 | CSA | VDE | EAC |
*For regulating heat exchangers and fans (e.g LE 019) and as an alarm contact for monitoring the interior temperature of electronic enclosures.